Ready to go further?

divider

Simply click the link below to access our contact form or just call us and you will make a step towards a greener approach.

form button

1-877-525-8118 (Canada and USA)
+1.514.525.8118 (International)

divider

Testimonials

Testimonials

T_1

Whether you have a small boiler to heat your building or a huge biomass cogeneration boiler, we have a testimonial to share with you. We have been treating boilers for over 20 years and have made a difference for the owners and operators.

Our sectors of expertise include Pulp and Paper, Petrochemicals, Rubber, Textile, Agro-food, Lumber, Institutional, Hospitals, Cogeneration, Metal works, Construction, Plastics, Cement, Hygiene, Pharmaceutical, Chemicals, etc.


one-col-divider

T_2Benefits: Read some some excerpts from Testimonial Letters

CHUS (Sherbrooke University Hospital Center)
–Hotel –Dieu Facility (Hospital)

“This product is natural, biodegradable and non toxic. It replaces the three usual products that we have been using for decades. It has more benefits to it: use less water to produce the same amount of steam and our energy reduction for this site is estimated at $25 000/year.”

one-col-divider
T_3Unilever Canada – Baie D’Urfe Plant (Agrofood)

“We treated our boilers with “traditional” products containing sulphites, phosphates and amines. The boiler water conductivity oscillated between 3000 and 4000 micromhos, and our blowdown rate ranged between 6.5% and 8.5%.

After a thorough study of MK3106 and contact with references that have already used the product for several years, we decided to replace our products by this product containing purified tannins.

As of the first week, we noted a drastic reduction in boiler blowdows. The boiler now oscillates between 8500 and 10,000 micromhos, we even reached several times more than 200 concentration cycles, meaning a 0.5% purge rate.“

The results are amazing; the conductivity of the steam  oscillates between 6 and 18 micromhos with a pH between 8.1 and 8.6 on average. The total iron tests carried out are close to 0.03 mg/l and we did not notice any corrosion in our steam network.

All Servivap commitments were fulfilled, from the quality of their service to the performance of their product.”

one-col-divider

T_4Beaulieu Canada (Textile) – Case study published in Industrial Water World

“Servivap Canada Inc.’s tannin additive for boiler water has eliminated scaling problems for carpet conglomerate Beaulieu Canada and cut its energy costs by $200,000 per year...  blowdown has plunged 80% because boilers can operate at much higher conductivity levels...  It operates more than 200,000 PPH of boiler capacity at a spinning plant at Wickham and manufacturing plants at Acton Vale and Farnham… Beaulieu said conventional water treatments with sulfites, phosphates, phosphonates and amines failed to alleviate its scale and corrosion problems... Purified tannins... allows boilers to operate in a range of 8,000 to 10,000 micromhos of conductivity, cutting blowdown volume without carryoverof contaminants into the steam”

one-col-divider

T_5Cascades Canada - East Angus Plant (Pulp and Paper)

“The accumulated production of all the boilers provides 285,000 PPH… we substituted the traditional products with just one, MK 3106 from Servivap. We began using the product for a limited time as a test. From that first test day, we have never looked back and have used it ever since.

...The MK3106 is used between 6000 and 9000 mmhos.  It is at these concentrations that it finds its full potential. The product is injected at the same place as old products.

...The annual boiler inspections were positive in the months that followed implementation of the product

...The frequency of the boiler blowdown was reduced by a significant amount, with a result that the Gas M3/TMV ratio produced is improved and the effluent flow also dropped.

...Servivap provides very good service to our factory… Each company that uses this product should improve their performance”

one-col-divider

Cooling tower and chillers

Our customers have seen their shutdown time reduced. They had to stop less often than with competing product to brush the chillers.

Would you like access to the full letters or to talk to people in your field that are using the product? To know how to improve your own facilities, fill out the form below or just call us: 1-877-525-8118.